Fire is arguably the single most dangerous hazard out at sea, where external help is unavailable and evacuation is the absolute last resort. Developing an ironclad foundation in fire prevention is mandatory for every single mariner. To help you kickstart your preparation, Nirzara introduces the FPFF Exit Exam Mock - Questions and Answers Set 1. This debut practice module focuses heavily on the basic physics of fire, standard fire classifications, and the fundamental operation of portable extinguishers on board merchant vessels.
This foundational set on Nirzara contains 30 highly repeated Multiple Choice Questions (MCQs) mapped precisely to the latest DG Shipping online exam portal. You will face essential STCW questions regarding the fire triangle components (oxygen, heat, and fuel), identifying different classes of fire (Class A to Class E), and selecting the appropriate extinguishing agent for electrical or galley fires. Because choosing the wrong extinguishing media can catastrophically worsen an engine room fire, the computer-based exam tests these basic definitions very strictly.
Every question inside Nirzara's Set 1 features its direct, verified correct answer, offering an instant assessment of your basic safety knowledge. The DG Shipping exit portal frequently relies on fundamental principles to check your accuracy under pressure. Spend a few minutes solving these 30 targeted questions today on Nirzara to iron out your foundational doubts, sharpen your answering speed, and securely pass your fire fighting exam on the very first try!
Practice with 30 questions from the BASIC FPFF COURSE bank. Each question is verified and explained.
MCQ Practice Questions (30)
Live Mock TestQuestion 1 / 30
Time Left: 15:00
Loading question...
🎉 Mock Test Complete
Your Examination Result
0 / 30
Score Percentage: 0%
Correct
0
Incorrect
0
Skipped
0
1
"In what language/languages shall the fire control plans/folders (or copies of plans and folders) be?"
aThe English language
bThe Flag State language with copies in English or French
cThe Flag State language with copies in English
dThe Flag State language
Correct Answer: Option C
Imported via XML Feed
2
"Fuel oil from a leaking fuel pipe has been collected in a drip tray under the boiler furnace. The oil is suddenly ignited by a backflash from the boiler burner. The boiler room is manned and the person present has the choice of various extinguishers. The fire is purely a surface fire. What would be the preferable extinguisher?"
aPowder
bAny of the mentioned alternatives
cCO2
dWater
Correct Answer: Option A
Imported via XML Feed
3
"Which of the following types of breathing apparatus are most likely to be found onboard a modern ship?"
aOxygen Breathing Apparatus.
bCompressed Air Breathing Apparatus.
cGas Mask type Breathing Apparatus.
dAtmospheric Breathing Apparatus.
Correct Answer: Option B
Imported via XML Feed
4
"In addition to a fire suit, a fireman's outfit also comprises breathing apparatus and a fireproof lifeline. According to SOLAS- how many such sets of fireman's outfit are required to be carried by all ships?"
aAt least one.
bAt least two.
cAs required by the ship's administration.
dAt least three.
Correct Answer: Option B
Imported via XML Feed
5
Fire extinguishers that contain _____ have a red band located above them
aCarbon Dioxide
bWater
cFoam
dWet Chemicals
Correct Answer: Option B
Imported via XML Feed
6
"If you were put in charge of a fire team what is the minimum number of men wearing BA sets that you would allow to enter a smoke-filled compartment?"
a2 men
b1 man
c4 men
d3 men
Correct Answer: Option A
Imported via XML Feed
7
"In the case of diesel driven fire pumps, for how long period shall the fuel tank capacity allow the pump to be run at full capacity?"
aOne hour
bFifteen hours
cThree hours
dSix hours
Correct Answer: Option C
Imported via XML Feed
8
"A' class (fire) divisions are those divisions formed by bulkheads and decks. Which of the following requirements does not comply with the rules?"
aPreventing passage of smoke and flame to the end of a one-hour standard test
bSuitably stiffened
cInsulated on both sides with approved non-combustible material
dConstructed of steel or other equivalent material
Correct Answer: Option C
Imported via XML Feed
9
What type of fire hose nozzles must be available on board?
aDual purpose (jet/spray) type incorporating shutoff.
bJet type.
cDual purpose (jet/spray type).
dSpray type.
Correct Answer: Option A
Imported via XML Feed
10
What information is found on a ship's fire plan?
aThe duties of each crew member in case of fire
bThe signal used on the ship to indicate there is a fire.
cThe action to take if you heard the fire alarm.
dThe locations of various firefighting appliances and equipment.
Correct Answer: Option D
Imported via XML Feed
11
In fire-fighting, what does the term 'boundary starvation' refer to?
aCooling the area around a fire to stop it spreading
bClosing doors and hatches at the boundary of a fire
cMustering fire fighters and materials in the area near the fire
dRemoving the fuel from the boundary of a fire to stop it spreading further
Correct Answer: Option D
Imported via XML Feed
12
What are class 'C' bulkheads?
a"A. Bulkheads constructed of approved non-combustible materials that can withstand the standard
fire test for 30 minutes."
b"B. Bulkheads constructed of approved non-combustible materials that can withstand the standard
fire test for 45 minutes."
c"C. Bulkheads constructed of approved non-combustible materials that can withstand the standard
fire test for 15 minutes."
d"D. Bulkheads constructed of approved non-combustible materials but do not meet any of the
requirements relative to smoke and flame nor limitations relative to temperature rise."
Correct Answer: Option D
Imported via XML Feed
13
"Welding and use of open flames on board tankers (without COW and IGS) in operation are subject to regulations laid down by the Norwegian Maritime Directorate (Norwegian Ship Control Legislation - NSCL). Which of the listed requirements regarding washing and gas freeing before hot work in cargo tanks corresponds to these regulations?"
aAll cargo tanks, pump rooms and cofferdams shall be examined by type approved two
explosimeters.
bGas measuring can be carried out by all deck officers.
cOne type approved explosimeter shall be used for gas measuring.
dHatches to not adjacent tanks which have not been cleaned or inerted shall be kept open during work.
Correct Answer: Option A
Imported via XML Feed
14
"Under ISO standard 3941 (used mostly in Europe), a fire involving a flammable solid fuel would be classed as which of the following?"
aClass A.
bClass B.
cClass C.
dClass D.
Correct Answer: Option A
Imported via XML Feed
15
"In addition to cargo & machinery spaces which other spaces if any have to be fitted with an approved fixed firefighting system on cargo ships?"
aNo additional fixed systems are required.
bRope store
cPaint store
dFocsle store
Correct Answer: Option C
Imported via XML Feed
16
Which of the following statements is NOT correct about high expansion foam?
aIt extinguishes by smothering.
bIt has only a limited cooling effect.
cYou cannot survive in H.E. foam as the oxygen content is reduced.
dYou can survive in H.E. foam by breaking the bubbles to release the air.
Correct Answer: Option C
Imported via XML Feed
17
What type of construction material should be avoided regarding fire protection purposes?
aAll uncovered wooden materials
bAll composite materials
cAll plastic materials
dAll combustible materials
Correct Answer: Option D
Imported via XML Feed
18
"Where can shore side personnel find necessary information on ship's fire control systems in an emergency situation?"
aFrom the duty officer.
bA copy of the fire control plan is permanently posted in prominently marked locations onboard ships.
cA copy of the fire control plans/folders is stored in a watertight and prominently marked
container outside the deckhouse or accommodation.
dInformation is to be given by the owners through the nearest rescue center.
Correct Answer: Option C
Imported via XML Feed
19
Oily rags and metal twist pose a particular fire hazard because:
aThey are not a hazard unless ignited.
bThey generate their own oxygen when ignited and are therefore difficult to extinguish.
cThey are liable to spontaneous combustion.
dThey are not a hazard.
Correct Answer: Option C
Imported via XML Feed
20
All waste receptacles shall be of non-combustible materials, built and equipped with:
aHinged self-closing cover
bPermanent means for lashing
cNo openings in sides and bottom
dRack for fire buckets
Correct Answer: Option C
Imported via XML Feed
21
Sanitary-, ballast-, bilge- or general service pumps may be accepted as fire pumps provided:
aThey can be started from a position outside the engine room
bThey are ready for use as fire pumps at any time
cThey are not normally used for pumping oil
dThey are fitted with automatic start connected to the fire alarm
Correct Answer: Option C
Imported via XML Feed
22
"In pump rooms and pipe tunnels 'flameproof' electric light fittings are generally fitted. This means that:"
aEven if a fire occurs, it will not consume the fitting
bThe fitting is completely gastight and no gas can enter into contact with the bulb and electric
connections
cThe electrical supply will disconnect automatically in cases of fire
dGas may enter, but even if an explosion takes place the fittings is so strong that the explosion
will be contained within it and will not be blow out
Correct Answer: Option D
Imported via XML Feed
23
"Which firefighting system is the most efficient and with the least side effects in the event of a fire in the engine room?"
aThe powder extinguishing system.
bThe central foam extinguishing system.
cThe sprinkler extinguishing system.
dThe central CO2 extinguishing system.
Correct Answer: Option D
Imported via XML Feed
24
"According to SOLAS - for carbon dioxide fire-fighting systems in machinery spaces the fixed piping system shall be such that"
a70 % of the gas can be discharged into space within 2 minutes.
b100 % of the gas can be discharged into space within 3 minutes.
c100 % of the gas can be discharged into space within two minutes.
d85 % of the gas can be discharged into space within two minutes.
Correct Answer: Option D
Imported via XML Feed
25
Water extinguishers are color coded
aRed
bBlue
cWhite
dBlack
Correct Answer: Option A
Imported via XML Feed
26
What is the maximum allowed suction head for the fire pump?
a4.5 meters.
b9 meters.
c1.5 meters.
d3 meters.
Correct Answer: Option A
Imported via XML Feed
27
Fuel flowing in a pipe is prone to which of the following ignition sources?
aHigh pressure action.
bFriction.
cStatic electricity.
dChemical reaction.
Correct Answer: Option C
Imported via XML Feed
28
"Three methods of fire protection regarding internal divisional bulk heading may be adopted in accommodation and service spaces in cargo ships. Which of the given methods do not correspond to present rules?"
aFitting of an automatic sprinkler, fire-detection and alarm system for the detection and extinction of fire in all spaces in which fire might be expected to originate"
bFitting of a fixed fire-detection and alarm system in all spaces where fire might be expected to originate. No accommodation space bounded by an 'A' or 'B' class division to exceed 500 m
cConstruction of all internal bulkheads of non-combustible class 'B' or 'C' divisions
dConstruction of all internal bulkheads of class 'A' divisions
Correct Answer: Option D
Imported via XML Feed
29
"Which of the following statements does not apply to fire doors in main vertical zone bulkheads and stairway enclosures in passenger ships?"
aIf normally locked they do not have to be self-closing.
bThey shall be of the self-closing type.
cThey shall be capable of being closed from a control station unless they are normally closed.
dThey can have hold back hooks not subject to control station release providing the emergency
plan details a person to close them.
Correct Answer: Option D
Imported via XML Feed
30
"Where will the ship's officers find necessary information regarding the ship's fire protection arrangement, fire-detection equipment and fire extinguishing appliances?"
aIn permanently exhibited muster list
bIn permanently exhibited fire control plans
cIn special instruction and information folder at all fire control stations
dIn permanent exhibited alarm instructions
Correct Answer: Option B
Imported via XML Feed
About Me
NIRZARA TEAM
Author & Contributor
The Nirzara Team is a group of dedicated marine professionals and educators committed to improving maritime learning through digital education. Our team works to provide quality study materials, practical knowledge, and career guidance to support seafarers and marine students worldwide.
Mock Test Info
Course NameBASIC FPFF COURSE
Mock Test1
Questions30
Students1,346
Test Time15 Minutes
BASIC FPFF COURSE
Mock Test Sets
▶FPFF Exit Exam Mock - Questions and Answers Set 1