FPFF Exit Exam Mock - Questions and Answers Set 10
By NIRZARA TEAM
Published: Apr 08, 2026 at 10:57 am
Share:
MARINE EXAM
15 min read
FPFF Exit Exam Mock - Questions and Answers Set 10
Successfully knocking down the visible flames of a shipboard fire is only half the battle won. The hidden pockets of residual heat left behind inside steel bulkheads, insulation panels, and cable trunks can easily cause a catastrophic re-ignition hours after the initial emergency is declared over. To help you master these critical post-fire management tactics, Nirzara introduces the FPFF Exit Exam Mock - Questions and Answers Set 10. This tenth milestone practice module focuses heavily on the mechanics of fire overhaul, gas-freeing operations, and establishing strict post-fire safety watches.
This specific set on Nirzara contains 30 high-frequency Multiple Choice Questions (MCQs) updated according to the latest DG Shipping online exam trends. You will encounter essential STCW questions regarding the identification of hidden hot spots using thermal imaging cameras, the correct way to vent toxic smoke from a cooled compartment, safety precautions before re-entering a flooded engine room, and preventing re-ignition in deep-fat fryer fires. Because premature ventilation can introduce fresh oxygen and trigger a secondary explosion, the computer-based test evaluates these precise tactical sequences very strictly.
Every question inside Nirzara's Set 10 features its direct, verified correct answer, providing a clean and efficient way to assess your advanced safety knowledge. The DG Shipping exit portal frequently relies on these real-world tactical scenarios to verify your structural presence of mind. Spend a few minutes solving these 30 targeted questions today on Nirzara to eliminate exam anxiety, sharpen your answering speed, and comfortably secure your passing marks on the very first try!
Practice with 30 questions from the BASIC FPFF COURSE bank. Each question is verified and explained.
MCQ Practice Questions (30)
Live Mock TestQuestion 1 / 30
Time Left: 15:00
Loading question...
🎉 Mock Test Complete
Your Examination Result
0 / 30
Score Percentage: 0%
Correct
0
Incorrect
0
Skipped
0
1
Things to remember before opening the door of a fire compartment
aSmoldering of fire
bFlash over/Back draft
cExplosion of flame
dAll of the above
Correct Answer: Option D
Imported via XML Feed
2
Total weight of a portable extinguisher should be more than
a20 Kgs
b23 Kgs
c30 Kgs
d35 Kgs
Correct Answer: Option B
Under SOLAS Chapter II-2, Regulation 10.3.2.1, the total mass of a portable fire extinguisher shall not exceed 23 kg. Therefore, an extinguisher with a total weight exceeding 23 kg is not classified as a standard "portable" unit suitable for single-person deployment. This regulatory limit ensures that fire extinguishers remain manageable and readily deployable by one individual during an emergency.
3
What action should be taken immediately after a fire has been extinguished?
aThey are liable to spontaneous combustion
bThey are not a hazard
cThey are not a hazard unless ignited
dThey generate their own oxygen when ignited and difficult to extinguish
Correct Answer: Option A
Immediately after a fire is extinguished, materials, particularly in Class A fires, retain significant latent heat and may still be undergoing pyrolysis or smoldering. These superheated or partially combusted materials are highly liable to spontaneous combustion upon re-exposure to oxygen, creating a substantial risk of re-ignition. Therefore, thorough overhaul, cooling, and continuous monitoring of the affected area are critical post-extinguishment actions, as mandated by SOLAS Chapter II-2 and sound maritime safety practices, to mitigate this inherent hazard.
4
Which ship shall be provided with international shore connection for supply of water as extinguishing media
aTankers
bAll ships of 500 GRT and upward
cPassenger ships carrying more than 36 passengers
dPassenger ships of 100 GRT and upward
Correct Answer: Option B
The requirement for an international shore connection, used for supplying water to a ship's fire main from shore-side facilities, is mandated by SOLAS Chapter II-2, Regulation 10.2.1.7. This regulation explicitly states that all ships of 500 gross tonnage and upward shall be provided with at least one such connection. This standard ensures universal interoperability for firefighting efforts across a wide range of vessels.
5
Which side of the fire triangle most commonly causes a fire ?
aFoam
bPaper
cWood
dSteel
Correct Answer: Option B
Paper is a ubiquitous Class A combustible material found as documents, charts, and packaging on any vessel, presenting a constantly available and easily ignitable fuel source. Its relatively low ignition temperature and readiness to ignite from common shipboard ignition sources, such as electrical faults or hot work sparks, mean it is most frequently the *initial fuel* involved in starting a fire. Consequently, strict control over combustible materials, particularly paper waste and stores, is a fundamental aspect of fire prevention in accordance with SOLAS and STCW regulations.
6
In order to produce a high velocity water fog using a all purpose nozzle, you must
aPull the nozzle handle halfway back
bPull the nozzle handle completely forward
cInsert an in-line fog applicator
dChange to a small nozzle tip after changing the position of the nozzle handle
Correct Answer: Option A
Pulling the nozzle handle halfway back on an all-purpose nozzle precisely adjusts the internal baffling to create a finely atomized water spray while retaining significant pressure and forward velocity. This specific intermediate position is engineered to produce a high-velocity fog pattern, which is vital for effective boundary cooling, managing smoke and hot gases, and providing a protective screen during shipboard firefighting operations. Adherence to this correct operational technique is a fundamental requirement under STCW standards for fire prevention and firefighting.
7
To operate the fire extinguisher, the acronym PASS is often used to help us remember to
aPull the pin, aim at the base of the fire, squeeze the handle and sweep at the base of the fire
bPass by the fire, activate the fire alarm, select the proper extinguisher, shoot at the base of the fire
cPull the alarm, alert the response team, shut down the power sources, secure the area
dPass by the fire, activate the sprinkler system, seal fire area from oxygen, stop unauthorised entry
Correct Answer: Option A
The acronym PASS is a fundamental mnemonic device taught in STCW Basic Fire Fighting and Fire Prevention training, representing the critical steps for effectively operating a portable fire extinguisher. Option A correctly outlines this universally accepted procedure: **P**ull the pin, **A**im at the base of the fire, **S**queeze the handle, and **S**weep at the base of the fire. Adhering to these steps ensures proper and safe fire suppression in accordance with international maritime safety standards, vital for initial response onboard any vessel.
8
What class of fire was a wet chemical fire extinguisher specifically designed to fight?
aClass A fires
bClass D fires
cClass F / K fires
dClass B fires
Correct Answer: Option C
Wet chemical fire extinguishers are specifically engineered to combat Class F (European/International standard) or Class K (US standard) fires, which involve combustible cooking oils and fats. These fires, common in galleys and mess decks, burn at extremely high temperatures, and the wet chemical agent creates a saponification layer to cool the fuel and prevent re-ignition. This specialized capability ensures effective fire suppression for these unique hazards, aligning with maritime safety regulations like SOLAS chapter II-2.
9
In a mixture of flammable vapor and air, if there is too much vapor and not enough air to support combustion, we say the mixture is
aToo rich
bOver concentrated
cToo lean
dSaturated
Correct Answer: Option C
Imported via XML Feed
10
In order to put out a oil fire you should aim the foam type fire extinguisher;
aHit the vertical bulkhead wall near the fire
bAt the bottom and circle around the fire
cAt the base of the fire and sweep back and forth
dIn the middle of the flame
Correct Answer: Option A
Aiming the foam extinguisher at a vertical bulkhead wall near the oil fire enables the foam to gently 'bank down' and flow smoothly across the burning liquid surface. This indirect application method, a fundamental technique for Class B liquid fires as per maritime firefighting standards, prevents agitation and splashing of the burning fuel. It ensures the foam forms an effective, oxygen-excluding blanket that smothers the fire without spreading the hazard.
11
One of the uses for low velocity fog is to;
aHelp produce mechanical foam
bBreak apart class “A” combustibles
cSweep burning liquids overboard
dNone of the above
Correct Answer: Option D
Low velocity fog is primarily employed for deep-seated Class A fire attack, structural cooling, and heat absorption, not for physically breaking apart combustibles or sweeping burning liquids. While the water discharge from a low velocity applicator can be a component of a mechanical foam system, the fog itself does not directly "produce" the foam. Consequently, none of the provided options accurately describe a primary or correct use of low velocity fog according to established maritime firefighting principles.
12
A class D fire would involve the burning
aDiesel oil
bMagnesium
cDunnage
dElectrical insulation
Correct Answer: Option B
A Class D fire is specifically defined as one involving combustible metals. Magnesium is a highly reactive metal, and its combustion falls squarely into this category, requiring specialized extinguishing agents. Therefore, a fire involving magnesium is unequivocally classified as Class D under international maritime safety standards.
13
What type of release is allowed for fixed gas fire extinguishing installation onboard
aAny automatic release system
bA manually operated release only
cAn automatic release system activated by fire alarm
dAn automatic release system activated by fire detectors
Correct Answer: Option B
Fixed gas fire extinguishing installations, such as CO2 systems, create an immediate life-threatening atmosphere in the protected space by displacing oxygen. Consequently, to ensure the absolute safety of personnel onboard, international maritime regulations, specifically SOLAS Chapter II-2, strictly mandate that these systems are fitted with a manually operated release mechanism only. This design prevents accidental or premature discharge, ensuring all crew members can be safely evacuated from the protected space before activation.
14
"Three methods of fire protection regarding internal divisional bulk heading may be adopted in accommodation and service spaces in cargo ships. Which of the given methods do not correspond to present rules?"
aFitting of an automatic sprinkler, fire-detection and alarm system for the detection and extinction of fire in all spaces in which fire might be expected to originate"
bFitting of a fixed fire-detection and alarm system in all spaces where fire might be expected to originate. No accommodation space bounded by an 'A' or 'B' class division to exceed 500 m
cConstruction of all internal bulkheads of non-combustible class 'B' or 'C' divisions
dConstruction of all internal bulkheads of class 'A' divisions
Correct Answer: Option D
Imported via XML Feed
15
Minimum capacity of emergency fi re pump?
a15 M3/Hr.
b20 M3/Hr.
c25 M3/Hr.
d30 M3/Hr.
Correct Answer: Option C
Option C, 25 M3/Hr., is correct as per SOLAS Chapter II-2, Regulation 10.2.2.4.2.1.2. This regulation specifies that the emergency fire pump on cargo ships of 2,000 gross tonnage and upwards shall have a capacity of not less than 25 m3/h. This ensures a fundamental level of firefighting capability, capable of delivering at least two water jets at the required pressure even if the main fire pumps are inoperable.
16
Instructions for ‘Preparation for welding or hot work in cargo tanks’ is laid down by the Norwegian Maritime Directorate. During ongoing inspection on work in cargo tanks, the gas concentration shall be measured;
aAt one level for at least two places in the tank
bAt three levels at one point close to the working area
cAt three levels for at least two places in the tank
dAt two levels for three places in the tank
Correct Answer: Option C
Measuring at three distinct levels (top, middle, bottom) is imperative to account for gas stratification within the tank, as gases of different densities will accumulate at varying heights. Furthermore, sampling at a minimum of two separate locations ensures that the entire tank volume is accurately assessed, identifying any localized hazardous pockets during ongoing hot work and aligning with stringent confined space entry and hot work safety protocols. This comprehensive approach is a cornerstone of maritime safety regulations for hot work in cargo tanks.
17
Where shall manually operated call points in fixed fire- detection and alarm systems be located in accommodation spaces? (SOLAS II-2/13.2.1)
aIn all crew and passenger cabins
bIn messrooms, public lounges and other public rooms
cIn stairways and escape routes
dAt exits and in corridors
Correct Answer: Option D
Manually operated call points in accommodation spaces are precisely mandated by SOLAS Chapter II-2, as referenced, to be located at each exit and readily accessible throughout corridors. This strategic placement ensures maximum visibility and accessibility for prompt activation of the fire alarm system, which is critical for early warning during an emergency. Such positioning guarantees that no part of a corridor exceeds a specified distance from a call point, facilitating rapid reporting of a fire in accordance with maritime safety standards.
18
Class A divisions formed by bulk heads and constructed with steel or other equipment material and suitably stiffened
aTrue
bFalse
Correct Answer: Option A
Class A divisions are indeed required to be constructed of steel or other approved material, suitably stiffened, and form fire-resisting bulkheads as per SOLAS regulations for vessel subdivision and fire safety. These structural requirements are fundamental to maintaining the integrity of the ship's watertight and fire zones, ensuring passenger and crew safety in the event of damage or fire. Therefore, the statement accurately describes the construction and purpose of Class A divisions.
19
Carbon di- oxide is heavier than air
aTrue
bFalse
Correct Answer: Option A
Imported via XML Feed
20
Once the fire is contained, the master needs to evaluate the best strategy for the next stage , This might include a number of actions. In your opinion, which action does not belong?
akeeping the fire contained
bRe-introducing air circulation by opening up fire dampers and other openings
cOther means of control
dThe use of fixed installations to put out the fire contained
Correct Answer: Option B
Re-introducing air circulation by opening fire dampers and other openings after a fire has been contained is a critical error and fundamentally incorrect. This action supplies oxygen to superheated gases and smoldering materials, creating an immediate and severe risk of re-ignition, backdraft, or flashover, thereby jeopardizing the vessel and personnel. Maintaining compartment integrity and limiting oxygen is paramount in post-containment fire strategy, as per SOLAS Chapter II-2 and established maritime safety protocols.
21
International shore coupling is carried on all ships
aTrue
bFalse
Correct Answer: Option A
The International Shore Connection is a mandatory fitting on all ships, designed to allow shore-based fire services to connect their hoses to the ship's fire main system for emergency assistance. This crucial safety device is required by SOLAS Chapter II-2, Regulation 10.2.1.2.4, ensuring global interoperability for effective firefighting operations.
22
The elements needed for a fire include
aFuel
bOxygen
cHeat
dAll of the above
Correct Answer: Option D
For combustion to occur, all three elements—fuel, oxygen, and heat—are indispensable components, forming what is known as the "Fire Triangle" in maritime safety and engineering. This fundamental principle, ingrained in STCW and SOLAS fire prevention training, dictates that a fire cannot initiate or sustain itself without the simultaneous presence of adequate quantities of each. Consequently, all listed options are necessary elements, making "All of the above" the correct answer.
23
Ideally the adjustable jet/spray nozzle on a hose should be used as
aA spray of arc 60 degrees
bA jet
cA spray of arc 30 degrees
dA spray of arc 90 degrees
Correct Answer: Option A
Imported via XML Feed
24
Who has the authority to pull the fire alarm after discovering a fire on the worksite
aOnly Mater can activate the fire alarm
bAnyone who has seen a fire can activate the fire alarm
conly the fire safety officer activate the fire alarm
donly the crew can activate the fire alarm
Correct Answer: Option B
Maritime safety standards, underpinned by SOLAS and STCW, prioritize immediate alarm activation upon discovering a fire to prevent escalation and ensure rapid response. Any person who identifies a fire has the critical responsibility and the authority to activate the fire alarm without delay. This universal duty ensures that all personnel contribute to the earliest possible detection and mitigation of an emergency, which is fundamental to onboard safety.
25
What type of fire extinguisher should you use in order to extinguish a fire caused by solid materials, such as wood, paper or textile?
aCarbon Dioxide
bWater
cFoam
dWet Chemical
Correct Answer: Option B
For fires involving Class A materials like wood, paper, and textiles, water is the most effective extinguishing agent as it cools the burning material below its ignition temperature, removing the heat source required for combustion, a principle aligned with SOLAS and maritime safety standards for shipboard firefighting. The ability of water to absorb significant heat energy makes it the primary choice for extinguishing these types of fires, preventing re-ignition and ensuring effective extinguishment according to established marine engineering practices.
26
Passenger ships of 4000 GRT and above shall have at least _____ Pumps
a2
b3
c4
d1
Correct Answer: Option B
SOLAS Chapter II-1, Regulation 24 mandates that passenger ships of 4000 GRT and above must be equipped with at least three main bilge pumps, ensuring redundancy for effective drainage in emergencies. This requirement is crucial for maintaining watertight integrity and ensuring the safety of passengers and crew. The third pump provides a vital backup in case one of the primary pumps fails or is rendered inoperable.
27
Fully pressurized gas carriers are designed for excess pressure in cargo tank above?
a7 bar
b8 bar
c11 bar
d15 bar
Correct Answer: Option D
Imported via XML Feed
28
Water tight sliding steel doors used below water line must be able to close in 45 seconds or less when ship is in upright condition
aFalse
bTrue
Correct Answer: Option A
The statement is false because SOLAS Chapter II-1, Regulation 13.7.1, mandates that power-operated sliding watertight doors must be capable of closing by remote control in not more than 60 seconds when the ship is in the upright condition. Therefore, requiring closure in 45 seconds or less as an absolute maximum for all such doors is incorrect according to international regulations.
29
"In what language/languages shall the fire control plans/folders (or copies of plans and folders) be?"
aThe English language
bThe Flag State language with copies in English or French
cThe Flag State language with copies in English
dThe Flag State language
Correct Answer: Option C
Imported via XML Feed
30
Fire of carbonaceous substances is known as
aClass B Fire
bClass A fire
cClass C fire
dClass D fire
Correct Answer: Option B
Carbonaceous substances, such as wood, paper, and textiles, are solid combustible materials, and fires originating from them are classified as Class A fires according to international maritime safety standards, including SOLAS and STCW. These fires require specific firefighting agents like water or foam to cool the burning material and extinguish the flames. Class B fires involve flammable liquids, Class C fires involve energized electrical equipment, and Class D fires involve combustible metals, none of which accurately describe the combustion of carbonaceous materials.