While hands-on firefighting skills are essential during an actual crisis, a ship's ultimate safety relies heavily on statutory regulations, standardized emergency signaling, and strategic planning. Knowing how to read a vessel's structural safety layout before thick smoke hits the alleyways can save invaluable minutes during an emergency. To ensure you completely understand these statutory frameworks, Nirzara presents the FPFF Exit Exam Mock - Questions and Answers Set 7. This seventh practice module focuses deeply on international maritime safety codes, interpreting the Fire Control Plan, and managing routine fire drill protocols on board merchant vessels.
This specific set on Nirzara contains 30 highly repeated Multiple Choice Questions (MCQs) structured around the latest DG Shipping online portal guidelines. You will face essential STCW questions regarding the standard symbols used on a Fire Control Plan, the mandatory location of these plans outside the accommodation area for shoreside fire brigades, the regulatory frequency of shipboard fire drills under SOLAS, and the organization of firefighting parties according to the muster list. Because regulatory compliance is heavily tested to verify structural knowledge, the computer-based exam evaluates these legal safety definitions very strictly.
Every MCQ inside Nirzara's Set 7 comes paired with its verified correct answer, offering an instant checkpoint for your revision. The DG Shipping exam frequently tests precise locations, signaling patterns, and international symbol configurations to check your attention to detail under simulated stress. Spend a few minutes practicing with these 30 targeted questions today on Nirzara to eliminate confusion, sharpen your exam-taking speed, and comfortably secure your passing marks on the first try!
Practice with 30 questions from the BASIC FPFF COURSE bank. Each question is verified and explained.
MCQ Practice Questions (30)
Live Mock TestQuestion 1 / 30
Time Left: 15:00
Loading question...
🎉 Mock Test Complete
Your Examination Result
0 / 30
Score Percentage: 0%
Correct
0
Incorrect
0
Skipped
0
1
Water extinguishers are color coded
aRed
bBlue
cWhite
dBlack
Correct Answer: Option A
Imported via XML Feed
2
What are yearly checks for Dry Chemical powder system on Tankers?
aMoisture and humidity
bInspect visually components, verify pressure regulator and agitate DCP
cOpen/Close valves for pump
dCheck gauges
Correct Answer: Option B
Option B accurately describes critical annual checks for Dry Chemical Powder (DCP) systems on tankers, as required by SOLAS Chapter II-2 and good marine engineering practice. A thorough visual inspection of all system components ensures structural integrity and readiness, while verifying the pressure regulator guarantees correct discharge parameters. Crucially, agitating the dry chemical powder prevents compaction, ensuring it remains free-flowing and effective for immediate fire-fighting capability.
3
In order to put out a oil fire you should aim the foam type fire extinguisher;
aHit the vertical bulkhead wall near the fire
bAt the bottom and circle around the fire
cAt the base of the fire and sweep back and forth
dIn the middle of the flame
Correct Answer: Option A
Aiming the foam extinguisher at a vertical bulkhead wall near the oil fire enables the foam to gently 'bank down' and flow smoothly across the burning liquid surface. This indirect application method, a fundamental technique for Class B liquid fires as per maritime firefighting standards, prevents agitation and splashing of the burning fuel. It ensures the foam forms an effective, oxygen-excluding blanket that smothers the fire without spreading the hazard.
4
"Welding and use of open flames on board tankers (without COW and IGS) in operation are subject to regulations laid down by the Norwegian Maritime Directorate (Norwegian Ship Control Legislation - NSCL). Which of the listed requirements regarding washing and gas freeing before hot work in cargo tanks corresponds to these regulations?"
aAll cargo tanks, pump rooms and cofferdams shall be examined by type approved two
explosimeters.
bGas measuring can be carried out by all deck officers.
cOne type approved explosimeter shall be used for gas measuring.
dHatches to not adjacent tanks which have not been cleaned or inerted shall be kept open during work.
Correct Answer: Option A
Imported via XML Feed
5
How often should you test your smoke alarms?
aEvery month
bEvery six months
cEvery year
dEvery five years
Correct Answer: Option A
Option A, "Every month," is the correct frequency for testing smoke alarms. This regular verification ensures the immediate operational readiness of critical fire detection systems, paramount for early fire detection and the safety of all personnel onboard. Such proactive maintenance is a fundamental requirement under the Safety Management System (SMS) and aligns with the stringent safety standards of SOLAS.
6
Ideally the adjustable jet/spray nozzle on a hose should be used as
aA spray of arc 60 degrees
bA jet
cA spray of arc 30 degrees
dA spray of arc 90 degrees
Correct Answer: Option A
Imported via XML Feed
7
What is kind of fixed fire fighting system that can be used on Main Engine room fire
aHigh expansion foam
bMedium expansion foam
cLow expansion foam
dAll of the above.
Correct Answer: Option D
All foam types (low, medium, and high expansion) are effective extinguishing agents for Class B fires, prevalent in main engine rooms, by smothering and cooling flammable liquids. While fixed high-expansion foam systems are specifically approved by SOLAS for total flooding of machinery spaces, all foam ratios can be incorporated into fixed systems to combat engine room fires, whether for total flooding or local application, depending on the specific hazard and system design.
8
Maximum Temperature of unexposed side of a B-class division is?
a300 Deg C
b350 Deg C
c400 Deg C
d225 Deg C
Correct Answer: Option D
According to the International Code for Application of Fire Test Procedures (FTP Code) referenced by SOLAS, B-class divisions must prevent the passage of flame for at least 30 minutes. During the standard fire test, the average temperature on the unexposed side of a B-class division must not rise by more than 140°C above the initial temperature, and at no single point should the temperature rise by more than 180°C above the initial temperature, nor exceed an absolute maximum of 225°C. Thus, 225°C is the maximum allowable temperature at any single point on the unexposed side of a B-class division.
9
Automatic fire dampers in ventilation systems are operated by use of.
aHeat or smoke detectors
bC02 system pressure switches
cRemotely operated valves
dFusible links
Correct Answer: Option D
Automatic fire dampers in ventilation systems primarily utilize fusible links for their automatic operation. These links are specifically designed to melt at a predetermined elevated temperature, which then releases a spring-loaded or counterweighted mechanism, causing the damper blade to close automatically. This passive, localized activation is critical for compartmentalizing fire and preventing the spread of smoke and flames through ductwork, as required by SOLAS regulations for fire integrity.
10
You are carrying out a search in a smoke filled compartment wearing BA. At what stage should you start to make your way out of the compartment?
aRegularly check your pressure gauge and note how much air you used to reach you work area. Start to return when you have this amount left plus a reasonable reserve
bWait for the appropriate signal on your safety line as the personnel outside will be keeping a track of the time you have spent inside
c15 minutes after starting to used the set as this leaves you with five minutes air left
dWait until the BA set warning whistle sounds
Correct Answer: Option A
Option A correctly outlines the fundamental principle of proactive air management for BA operations in hazardous environments. By regularly monitoring your pressure gauge and calculating your return air requirement based on entry consumption plus a reasonable reserve, you ensure a safe and controlled exit in accordance with established maritime safety and firefighting procedures. This self-reliant method, often termed the 'rule of thirds,' is paramount for individual safety and preventing over-reliance on reactive measures.
11
A self contained Breathing apparatus should contain at least 1200 Litres of air. How long it should last a normal person when not carrying out hard work?
a45 Mins
b30 Mins
c15 Mins
d60 Mins
Correct Answer: Option B
Imported via XML Feed
12
What is the job for the ship management team when the fire breaks out?
aThe ship management team must fight the fire and then call the fire squads
bThe ship management team must call shore office for assistance.
cThe ship management team must evacuate the ship
dThe ship management team must call the nearest fire brigade and police station
Correct Answer: Option A
Imported via XML Feed
13
Which of the tools is designed for connecting and disconnecting fire hose coupling
aVise grips
bChannel locks
cC-Spanner
dPipe wrench
Correct Answer: Option C
The C-Spanner is the correct tool, specifically designed for the safe and efficient connection and disconnection of fire hose couplings. Its unique C-shaped design precisely engages the lugs on standard maritime fire hose fittings, providing proper leverage to prevent damage and ensure a secure, leak-free connection. This dedicated tool is essential for maintaining the integrity and readiness of shipboard firefighting systems, in accordance with SOLAS requirements for fire safety equipment.
14
Which type of fire extinguish do you use to fight an electrical fire if a carbon dioxide extinguisher is unavailable?
awater
bWet Chemical
cfoam
dDry powder
Correct Answer: Option D
For an electrical fire (Class C) where a carbon dioxide extinguisher is unavailable, Dry Powder is the appropriate alternative because it is a non-conductive agent that effectively smothers the fire by interrupting the chemical reaction, preventing electrocution hazards. This selection adheres strictly to maritime safety regulations and SOLAS Chapter II-2 guidelines, which prohibit conductive agents like water or foam on live electrical equipment.
15
With two pumps simultaneously delivering water through the nozzles the minimum pressures for cargo ships above 6000 GT shall be maintained at all hydrants at;
a0.25 N/mm2
b0.27 N/mm2
c0.30 N/mm2
d0.40 N/mm2
Correct Answer: Option B
According to SOLAS Chapter II-2, Regulation 10.2.1.4.1, the minimum pressure to be maintained at all hydrants on cargo ships of 6,000 gross tonnage and upwards, when two pumps are simultaneously delivering water, is 0.27 N/mm². This specific requirement ensures sufficient water flow and pressure are available throughout the fire main system for effective firefighting operations. Adhering to this standard is critical for maintaining maritime safety and compliance with international regulations.
16
Whilst in engine room you hear the CO2 release alarm, what action if any should you take
aTake no action as it is probably someone testing the system as the fire alarm has not been sounded and the engine room is not on fire
bProceed to the engine room and call the Bridge for further instructions
cAs CO2 can not kill you , secure present work and proceed out of engine room.
dLeave the engine room as quickly as possible closing all doors behind you.
Correct Answer: Option D
Upon hearing the CO2 release alarm, immediate and rapid evacuation of the engine room is the mandatory action due to the imminent and severe risk of asphyxiation as carbon dioxide rapidly displaces breathable oxygen. SOLAS regulations and all maritime safety standards dictate that personnel must prioritize their life and exit the hazardous space without delay, as CO2 is fatal. Closing all doors behind you is crucial for containing the extinguishing agent and any potential fire, preventing its spread and safeguarding adjacent compartments.
17
The highest concentration of hydrocarbon gas in air below which there is sufficient amount of hydrocarbon gas to support combustion is called.
aUpper Flammable limit
bLower Flammable limit
cIgnitable mixture
dNone of the above
Correct Answer: Option A
Imported via XML Feed
18
International shore coupling is carried on all ships
aTrue
bFalse
Correct Answer: Option A
The International Shore Connection is a mandatory fitting on all ships, designed to allow shore-based fire services to connect their hoses to the ship's fire main system for emergency assistance. This crucial safety device is required by SOLAS Chapter II-2, Regulation 10.2.1.2.4, ensuring global interoperability for effective firefighting operations.
19
What class of fire was a wet chemical fire extinguisher specifically designed to fight?
aClass A fires
bClass D fires
cClass F / K fires
dClass B fires
Correct Answer: Option C
Wet chemical fire extinguishers are specifically engineered to combat Class F (European/International standard) or Class K (US standard) fires, which involve combustible cooking oils and fats. These fires, common in galleys and mess decks, burn at extremely high temperatures, and the wet chemical agent creates a saponification layer to cool the fuel and prevent re-ignition. This specialized capability ensures effective fire suppression for these unique hazards, aligning with maritime safety regulations like SOLAS chapter II-2.
20
What is class of electrical fire?
aClass A
bClass B
cClass C
dNone of the above
Correct Answer: Option C
Electrical fires are specifically designated as Class C fires because they involve energized electrical equipment. This classification is crucial for maritime safety as it dictates the use of non-conductive extinguishing agents, such as CO2 or dry chemical, to effectively suppress the fire without posing an electrical shock hazard to personnel, aligning with STCW fire-fighting principles.
21
What are the criteria that it must be automatic fire detection on board
aIt is the owner’s option to have fire detection onboard a ship with heat/smoke detectors and audio alarm
bAll ships that are built after 1986
cAll ships covered by the IMO safety conventions
dAll ships that are built on or after 1986 in accordance with local rules and regulations
Correct Answer: Option C
Under the International Convention for the Safety of Life at Sea (SOLAS), a fundamental IMO safety convention, automatic fire detection systems are mandatory. Specifically, SOLAS Chapter II-2 dictates the comprehensive requirements for fire protection, detection, and extinction, applying to all ships covered by the convention. Therefore, all vessels subject to IMO safety conventions must have automatic fire detection to ensure minimum global safety standards for life and property at sea.
22
"Under ISO standard 3941 (used mostly in Europe), a fire involving a flammable solid fuel would be classed as which of the following?"
aClass A.
bClass B.
cClass C.
dClass D.
Correct Answer: Option A
Imported via XML Feed
23
Of the four kinds of fire extinguishers, which one would use on a class B fire
aWater
bCarbon Dioxide (CO2)
cFoam
dDry Chemical
Correct Answer: Option C
Foam is the correct extinguishing agent for Class B fires, which involve flammable liquids, because it creates an aqueous blanket that smothers the fire by separating the fuel from oxygen. This action effectively cools the fuel, prevents re-ignition, and is a primary method stipulated by maritime safety regulations like SOLAS and STCW for combating liquid fires on board vessels.
24
Carbon di- oxide is heavier than air
aTrue
bFalse
Correct Answer: Option A
Imported via XML Feed
25
You notice smoke coming from an open laundry room doorway. After activating the fire alarm, which of the following would you do FIRST?
aAttempt to determine what is burning.
bAcquire the nearest self-contained breathing apparatus.
cBreak out the nearest fire hose.
dWait for the fire team to arrive and assist as directed.
Correct Answer: Option A
After activating the fire alarm, the immediate priority under STCW basic fire fighting principles is to safely identify the class of fire. This crucial initial assessment, conducted from a safe distance, determines the appropriate extinguishing agent and method, providing vital information to the bridge and fire team for an effective and targeted response to prevent escalation.
26
How many emergency sources are require for fire-detection and fire alarm systems?
aTwo
bNone
cOne
dThree
Correct Answer: Option A
Fire detection and fire alarm systems are essential safety systems on board and, as mandated by SOLAS Chapter II-2, Regulation 7, require two independent emergency sources of power. This critical redundancy ensures continuous system operation and reliability even if one power supply fails, maintaining the vessel's ability to detect and alert to fire hazards. Therefore, Option A, "Two," is the correct answer to guarantee robust emergency preparedness.
27
________ are one of the most dependable ways to fight a fire
aWork Permits
bAutomatic sprinkler systems
cFire escapes
dJob safety analyses
Correct Answer: Option B
Imported via XML Feed
28
Class A materials do not include which of the following?
aWood Materials
bPropane Materials
cPlastic Materials
dPaper Materials
Correct Answer: Option B
Class A materials, in the context of fire classification, refer specifically to ordinary combustible solids such as wood, paper, and many plastics, which leave an ash when burned. Propane, however, is a flammable gas, which is categorized under Class B fires alongside flammable liquids. Therefore, propane is explicitly excluded from the definition of Class A materials.
29
Emergency escape routes should be kept
aOpen and clear
bLocked at sea
cLocked in port
dOpen when needed
Correct Answer: Option A
Imported via XML Feed
30
A closed interior door will slow the spread of;
aSmoke
bHeat
cFire
dAll the above
Correct Answer: Option D
A closed interior door acts as a vital physical barrier, effectively containing the immediate spread of smoke, restricting the transfer of heat, and thereby slowing the propagation of the fire itself. This adherence to compartmentation, a core tenet of SOLAS Chapter II-2 and marine engineering fire safety standards, is critical for protecting escape routes, adjacent compartments, and maintaining vessel integrity. By preventing the rapid advance of all three elements, the door provides essential time for emergency response and personnel safety.
About Me
NIRZARA TEAM
Author & Contributor
The Nirzara Team is a group of dedicated marine professionals and educators committed to improving maritime learning through digital education. Our team works to provide quality study materials, practical knowledge, and career guidance to support seafarers and marine students worldwide.