When dealing with large-scale shipboard fires, portable extinguishers quickly run out, leaving the main fire main system as your primary defense. Deploying high-pressure fire hoses and selecting the right nozzle settings requires tactical precision under immense physical stress. To ensure you can handle these heavy-duty firefighting operations safely, Nirzara presents the FPFF Exit Exam Mock - Questions and Answers Set 5. This fifth practice module focuses deeply on fire main operations, hose handling techniques, dual-purpose nozzles, and critical international safety interfaces.
This specific set on Nirzara contains 30 highly repeated Multiple Choice Questions (MCQs) structured around the latest DG Shipping online portal guidelines. You will face essential STCW questions regarding when to use a solid water jet versus a fine water spray, the structural dimensions and coupling specifications of the International Shore Connection (ISC), maintaining fire pump pressures, and safety precautions against hydrostatic shock in lines. Because a wrong nozzle selection inside a confined space can steam-scald an entry team, the computer-based exam evaluates these operational parameters very strictly.
Every MCQ inside Nirzara's Set 5 comes paired with its verified correct answer, offering an instant checkpoint for your revision. The DG Shipping exam frequently tests precise coupling thread dimensions and pressure regulations to verify your technical accuracy under pressure. Spend a few minutes practicing with these 30 targeted questions today on Nirzara to eliminate confusion, sharpen your exam-taking speed, and comfortably secure your passing marks on the first try!
Practice with 30 questions from the BASIC FPFF COURSE bank. Each question is verified and explained.
MCQ Practice Questions (30)
Live Mock TestQuestion 1 / 30
Time Left: 15:00
Loading question...
🎉 Mock Test Complete
Your Examination Result
0 / 30
Score Percentage: 0%
Correct
0
Incorrect
0
Skipped
0
1
Passenger ships of 4000 GRT and above shall have at least _____ Pumps
a2
b3
c4
d1
Correct Answer: Option B
Imported via XML Feed
2
What is the maximum allowed suction head for the fire pump?
a4.5 meters.
b9 meters.
c1.5 meters.
d3 meters.
Correct Answer: Option A
Imported via XML Feed
3
Low expansion foam is suitable for fighting fires in
aAccommodation
bCargo Holds
cDeck of a ship
dEngine Room
Correct Answer: Option C
Imported via XML Feed
4
Fire extinguishers that contain _____ have a red band located above them
aCarbon Dioxide
bWater
cFoam
dWet Chemicals
Correct Answer: Option B
Imported via XML Feed
5
Fire is a process of combustion accompanied by the rapid release of heat and ___ in varying intensities
aLight
bEnergy
cDestruction
dNone of the above
Correct Answer: Option B
Option B, 'Energy,' is the correct answer because fire is fundamentally an exothermic chemical reaction where chemical potential energy is rapidly converted and released. Heat is a primary form of this released energy, and light is another significant manifestation. Understanding this comprehensive energy release is critical for effective fire safety, prevention, and control, forming a cornerstone of maritime training under SOLAS and STCW.
6
Fire extinguishers are classified by
aThe type of fire they are used on
bSize of the fire put out
cThe temperature of fire
dThe colour of the fire
Correct Answer: Option A
Imported via XML Feed
7
In fire-fighting, what does the term 'boundary starvation' refer to?
aCooling the area around a fire to stop it spreading
bClosing doors and hatches at the boundary of a fire
cMustering fire fighters and materials in the area near the fire
dRemoving the fuel from the boundary of a fire to stop it spreading further
Correct Answer: Option D
Imported via XML Feed
8
If there is a black coloured band above the fire extinguisher; what does the colour of the band tell you?
aThat this extinguisher is a wet chemical fire extinguisher
bThat this extinguisher is a carbon dioxide fire extinguisher
cThat this extinguisher is broken and should not be used
dThat this extinguisher is broken and should not be used
Correct Answer: Option B
A black colored band displayed above a fire extinguisher definitively indicates that it contains carbon dioxide (CO2) as its extinguishing medium. This standardized color coding is a critical maritime safety convention, ensuring immediate and unambiguous identification of the extinguishing agent as mandated by SOLAS Chapter II-2 requirements for fire-fighting appliances. Proper identification through such banding is vital for selecting the correct extinguisher for the class of fire and ensuring effective fire suppression without risk.
9
Emergency escape routes should be kept
aOpen and clear
bLocked at sea
cLocked in port
dOpen when needed
Correct Answer: Option A
Imported via XML Feed
10
Fire _____ is based on the type of fuel used to feed a fire
aDetection
bClassification
cPrevention
dTheory
Correct Answer: Option B
Imported via XML Feed
11
A band of ____________ is displayed above a fire extinguisher that contains carbon dioxide.
aYellow
bRed
cBlack
dCream
Correct Answer: Option C
The correct answer is 'Black' because, in line with international maritime standards and fire safety equipment conventions, a black band displayed above a fire extinguisher consistently indicates that its extinguishing agent is carbon dioxide (CO2). This standardized color coding ensures immediate and unambiguous identification of the extinguisher's contents, which is vital for safe and effective firefighting operations onboard any vessel in an emergency.
12
Which of the following fire extinguishers is used to put out Class ‘A’ fires?
aCO2
bWater
cMulti – purpose dry chemical
dBoth b and c.
Correct Answer: Option D
Imported via XML Feed
13
Titanium and aluminum materials can be classified under which of the following categories?
aCategory A
bCategory C
cCategory D
dCategory B
Correct Answer: Option C
Titanium and aluminum materials, while metals, are not classified as non-combustible like steel under various marine fire safety regulations and require specific consideration due to their different fire properties and lower melting points. These lightweight structural alloys are often grouped under 'Category D' in certain maritime classifications, particularly within standards governing high-speed craft (HSC Code). This classification acknowledges their combustibility and rapid loss of strength at elevated temperatures, mandating specific fire protection and insulation measures to ensure equivalent fire safety performance compared to traditional steel structures.
14
__________ fire extinguishers are specifically designed in order to tackle a class F fire.
aCarbon Dioxide
bWet Chemical
cFoam
dWater
Correct Answer: Option B
Wet Chemical fire extinguishers are specifically formulated to create a saponification layer on burning cooking oils and fats, effectively smothering the fire, cooling the fuel, and preventing re-ignition. This makes them the designated and safest choice for Class F fires, which involve high-temperature cooking media, as mandated by maritime safety regulations for galley and catering areas.
15
Class C fires involve
aFire involving Gas/Electrical
bFire involving liquids
cFire involving solid material
dFire involving metal
Correct Answer: Option A
Imported via XML Feed
16
The Main objection to the use of a dry chemical fire extinguisher on an electrical fire is?
aExtinguishing action is not as good as with soda acid
bpowder conducts electricity back to the fire fighter
cDry chemical leaves a powder residue which may render electrical equipment inoperative
dExtinguisher need to be charged.
Correct Answer: Option C
The primary objection to using dry chemical on electrical fires is the significant residue it leaves. This corrosive and abrasive powder penetrates sensitive electrical contacts, circuit boards, and intricate equipment, inevitably causing extensive damage and rendering essential systems inoperative. While effective in extinguishing the fire, the costly and time-consuming post-fire cleanup and potential for long-term equipment failure make it an undesirable choice for critical electrical installations.
17
Fuel flowing in a pipe is prone to which of the following ignition sources?
aHigh pressure action.
bFriction.
cStatic electricity.
dChemical reaction.
Correct Answer: Option C
Imported via XML Feed
18
Which of the following does not need to be done right after a fire drill?
aHave a debriefing with all members of the safety committee.
bNote any defects in the equipment for repair or replacement.
cReturn all the equipment to its correct place.
dRecharge extinguishers and compressed air bottles.
Correct Answer: Option A
While debriefings are crucial for continuous improvement and learning, the immediate priorities right after a fire drill, as per SOLAS and good maritime safety practice, are to restore the vessel's operational readiness. Options B, C, and D are critical immediate actions to ensure all firefighting equipment is serviceable, accounted for, and ready for a real emergency, which directly impacts the vessel's safety posture. A formal debriefing with the entire safety committee, while essential, can be scheduled shortly after these urgent operational tasks are completed and does not need to occur *right after* the drill's conclusion to ensure immediate readiness.
19
Which of the following colours can be found in a band above a wet chemical fire extinguisher?
aYellow
bCream
cBlue
dRed
Correct Answer: Option A
According to international maritime safety standards and common industry practice, wet chemical fire extinguishers are distinctively identified by a yellow color band above the main cylinder body. This color coding ensures rapid and accurate identification of the extinguishing agent for Class F fires (cooking oils/fats) and other combustibles, critical for effective fire-fighting operations onboard vessels.
20
"Which of the following statements does not apply to fire doors in main vertical zone bulkheads and stairway enclosures in passenger ships?"
aIf normally locked they do not have to be self-closing.
bThey shall be of the self-closing type.
cThey shall be capable of being closed from a control station unless they are normally closed.
dThey can have hold back hooks not subject to control station release providing the emergency
plan details a person to close them.
Correct Answer: Option D
Imported via XML Feed
21
Carbon- dioxide(CO2) release alarm is fitted outside the engine room?
aTrue
bFalse
Correct Answer: Option B
Imported via XML Feed
22
How often should you test your smoke alarms?
aEvery month
bEvery six months
cEvery year
dEvery five years
Correct Answer: Option A
Option A, "Every month," is the correct frequency for testing smoke alarms. This regular verification ensures the immediate operational readiness of critical fire detection systems, paramount for early fire detection and the safety of all personnel onboard. Such proactive maintenance is a fundamental requirement under the Safety Management System (SMS) and aligns with the stringent safety standards of SOLAS.
23
After a fire has been extinguished in a closed space, personnel may safely enter the space
aSmoke density has decreased sufficiently to see the bulkhead opposite the compartment
bAll smoke and toxic fumes are removed and an adequate oxygen supply is present
cNone of the above
dAll of these
Correct Answer: Option B
Personnel may safely enter a post-fire space only after comprehensive atmospheric testing confirms the complete removal of all toxic combustion byproducts and an adequate oxygen supply is verified. This critical step ensures breathable air, preventing incapacitation or death from invisible gases and oxygen deficiency, in strict accordance with SOLAS and confined space entry regulations.
24
Fire spreads depends upon on air speed and calorific value of fuel ?
aTrue
bFalse
Correct Answer: Option A
Option A is correct because the propagation of fire on a vessel is directly governed by oxygen availability, which increases with air speed or ventilation, and the energy density of the combustible material, indicated by its calorific value. More oxygen supports more vigorous combustion, and fuels with higher calorific values release greater heat, thus intensifying and accelerating fire spread. Understanding these factors is fundamental to maritime fire prevention, detection, and firefighting strategies, as mandated by SOLAS and STCW standards.
25
The spread of fire by conduction is when two objects at different temperature are in contact with each other
aTrue
bFalse
Correct Answer: Option A
Imported via XML Feed
26
A red line on the fire plan indicate B-Class division
aTrue
bFalse
Correct Answer: Option A
True. On a ship's fire control plan, a solid red line is the internationally recognized symbol for indicating a B-Class division. This convention, established under SOLAS Chapter II-2, ensures personnel can quickly identify partitions designed to prevent the passage of flame for 30 minutes and limit temperature rise, which is critical for effective fire compartmentalization.
27
You should avoid using __________ fire extinguishers when extinguishing a fire in a confined space.
aDry Powder Fire Extinguishers
bWater Fire Extinguishers
cFoam Fire Extinguishers
dWet Chemical Fire Extinguishers
Correct Answer: Option A
Dry Powder Fire Extinguishers should be avoided in confined spaces due to the dense cloud of fine particulates they release, which severely reduces visibility and can cause significant respiratory distress. This obscuration and breathing difficulty can disorient personnel, impede escape routes, and create a serious risk to life, making them unsafe for use in such environments as per maritime safety regulations. Consequently, other extinguishing agents are preferred for fire fighting in confined spaces to ensure personnel safety and clear escape routes.
28
When do you go to the fire assembly point?
aWhen discussion about fire safety is taking place
bWhen the fire alarm goes on
cIf you are the first one to see the fire
dWhen practicing using the different types of fire extinguishers
Correct Answer: Option B
Upon activation of the fire alarm, all personnel are required to immediately proceed to their designated fire assembly point, also known as the muster station. This fundamental maritime safety procedure, mandated by SOLAS Chapter II-2 and emphasized in STCW basic safety training, ensures prompt accountability, provides immediate instructions, and facilitates an organized response to the emergency.
29
Hazards in accommodation
aFurnishing and personal effects
bCigarette smoking
cDefective electrical connections
dAll of the above
Correct Answer: Option D
Option D is correct because all listed items constitute significant hazards in accommodation spaces, directly impacting crew safety and vessel integrity. Furnishing and personal effects can pose fire risks from combustible materials or become unsecured projectiles in heavy weather, while cigarette smoking is a well-known ignition source, directly contradicting SOLAS Chapter II-2 fire prevention mandates. Defective electrical connections are a critical hazard, causing fires and electric shocks, underscoring the necessity for robust electrical maintenance in line with SOLAS Chapter II-1 and overall maritime safety standards.
30
"In the case of diesel driven fire pumps, for how long period shall the fuel tank capacity allow the pump to be run at full capacity?"
aOne hour
bFifteen hours
cThree hours
dSix hours
Correct Answer: Option C
Imported via XML Feed
About Me
NIRZARA TEAM
Author & Contributor
The Nirzara Team is a group of dedicated marine professionals and educators committed to improving maritime learning through digital education. Our team works to provide quality study materials, practical knowledge, and career guidance to support seafarers and marine students worldwide.